contact PIs:Data Object CTD
| name | title |
|---|---|
| Dr Giacomo DiTullio | Principal Investigator |
| Dr Robert B. Dunbar | Co-Principal Investigator |
Profile CTD data from CORSACS 1 cruise (NBP-0601) and CORSACS2 cruise (NBP-0608) to the Ross Sea in 2005 and 2006.
Collection of these data was funded by the NSF Office of Polar Programs as "Collaborative Research: Interactive Effects of Iron, Light and Carbon Dioxide on Phytoplankton Community Dynamics in the Ross Sea", NSF Award OPP-0338097.
The RVIB Nathaniel B. Palmer is equipped with a SeaBird Electronics Model SBE-911plus conductivity, temperature, and depth instrument, which is mounted on a SeaBird, epoxy coated 24-bottle rosette sampler. The sampler is equipped with a SeaBird pylon and 10-liter Bullister bottles. Data from dual temperature, dual conductivity, pressure, oxygen, and other instruments were transmitted in real-time to the SBE-11 deck unit via conducting cable. Onboard, the data were recorded digitally on a Windows computer running SBE Seasave software (ver.5.37d).
Prior to the start of each hydrocast, the CTD was lowered to a depth of 10 m to allow time for the CTD pumps to activate and the sensors to equilibrate. During this washing period, the differences between the primary and secondary readings of the temperature and conductivity were monitored as well as dissolved O2 levels. Once stability was achieved, the CTD was brought back to the surface in preparation for the hydrocast. During all hydrocasts, the CTD was lowered at a rate of 30 m min-1 through the upper water column (usually 150 m) and then at 50 m min-1 at greater depths. The distance between the sensor package and the bottom was determined using a Datasonics pinger. A mechanical safety switch notified the CTD operator when the package had reached a distance of 3 to 5 m from the bottom. We reached the seabed on about half of the hydrocasts conducted during both NBP0601 and NBP0608. The remaining casts focused on sampling the uppermost, biologically active portion of the water column. Ten-liter Bullister bottles were tripped at selected depths on the upcast to provide in situ sampling of chemical, biological, and physical properties of the water column as well as to provide calibration data for the CTD. Once the CTD was back onboard, the temperature, conductivity, and dissolved oxygen sensors were flushed with deionized water and covered with rubber boots to minimize instrument fouling between casts.
Detailed descriptions of calibration and processing are available in the full cruise reports (see the cruise specific data documentation). Those reports, along with the original data contributions were downloaded from Rob Dunbar's site at Stanford University on 15 May 2009: CTD data from Rob Dunbar.
| Parameter | Description | Units |
|---|---|---|
| cruise_id | ship's cruise designation | dimensionless |
| lat | latitude; North is positive, South is negative | decimal degrees |
| lon | longitude; East is positive, West is negative | decimal degrees |
| sta | station number | dimensionless |
| date | date of sampling; local or UTC unknown | YYYYMMDD |
| time | time of sampling; local or UTC unknown | hhmm |
| year_day | day of year for a specified year as a decimal; note that noon on Jan 1 is 1.5; range 1 to 366 | dimensionless |
| depth | sample depth, in meters | meters |
| temp_0 | temperature, from the CTD 'primary sensor', in degrees Celsius. | degrees Celsius |
| temp_1 | temperature, from the CTD 'secondary sensor', in degrees Celsius. | degrees Celsius |
| cond_0 | conductivity, from the CTD 'primary sensor', in Siemens/meter. | Siemens per meter |
| cond_1 | conductivity, from the CTD 'secondary sensor', in Siemens/meter. | Siemens per meter |
| sal_0 | salinity, calculated from the CTD 'primary sensor' in Practical Salinity Units (PSU) | dimensionless |
| sal_1 | salinity, calculated from the CTD 'secondary sensor' in Practical Salinity Units (PSU) | dimensionless |
| sigma_t | sigma-t density | kilograms per meter cubed - 1000 |
| density | density, from the CTD 'primary sensor' | kilograms per meter cubed |
| density_S | density, from the CTD 'secondary sensor' | kilograms per meter cubed |
| fluor | fluorescence, FIECO-AFL | volts |
| PAR | Photosynthetically Available Radiation (PAR) | microeinsteins per meter^2 per second |
| PAR_surface | surface PAR | microeinsteins per meter^2 per second |
| O2_0 | oxygen; CTD sensor 0 (primary) | milliliters per liter |
| O2_1 | oxygen; CTD sensor 1 (secondary) | milliliters per liter |
| O2_0_umol_kg | dissolved oxygen; CTD sensor 0 (primary) in micromoles per kilogram | micromoles per kilogram |
| O2_1_umol_kg | dissolved oxygen; CTD sensor 1 (secondary) in micromoles per kilogram | micromoles per kilogram |
| O2sat | oxygen saturation | milliliters per liter |
| O2_0_PS | unknown; primary sensor; percent saturation? | unknown |
| O2_1_PS | unknown; secondary sensor; percent saturation? | unknown |
| O2_volts_0 | oxygen in volts; primary sensor | volts |
| O2_volts_1 | oxygen in volts; secondary sensor | volts |
| RVIB Nathaniel B. Palmer NBP0601 | RVIB Nathaniel B. Palmer NBP0608 |
This document is created from the content of the BCO-DMO metadata database. 2010-03-13 01:01:35
info app: /home/bco/dbase-v2 v.100108 CLC